Saturday, January 19, 2019

'Vernier Caliper' (Volume-2) SolidWorks 2017 Tutorial






Serial No. 223-B


'Vernier Caliper' (Volume-2) SolidWorks 2017 Tutorial
(Rest of the model is designed in Volume-1 & 3)



 https://autode.sk/2FJZcMb




Click the following link to get the model file: - http://bit.ly/2oRyACK



The Procedure of reading of Vernier Caliper in Millimetre Scale
Total number of divisions imprinted on Linear Scale = 150
Total number of divisions imprinted on Vernier Scale = 50
Pitch of Linear Scale = total length of Linear scale/total number of divisions imprinted on
                                       Linear scale
                                    = 150 mm / 150 = 1 mm
Least count of Vernier Scale = Pitch of Linear scale / Total number of divisions on Vernier Scale
                                                = 1 mm / 50 = 0.02 mm
Reading of Linear Scale = Pitch of Linear scale x Number of divisions on Linear Scale just before the
                                             zero of Vernier Scale
                                          = 1 mm x 12 = 12 mm
Reading of Vernier Scale = Least count of Vernier Scale x Number of divisions of Vernier Scale
                                              aligned with the marking of Linear Scale
                                           = 0.02 mm x 28 = 0.56 mm
Total Reading = Reading of Linear Scale + Reading of Vernier Scale
                         = 12 mm + 0.56 mm = 12.56 mm = 1.256 cm
__________________________________________________________________
Procedure of reading of Vernier Caliper in Inch Scale
Total number of divisions imprinted on Linear Scale  = 240
Total number of divisions imprinted on Vernier Scale = 25
Pitch of Linear Scale = total length of Linear scale/total number of divisions imprinted
                                        on Linear scale
                                     = 6 inch / 240= 0.025 inch
Least count of Vernier Scale = Pitch of Linear Scale / Total number of divisions on Vernier scale
                                                = 0.025 inch / 25 = 0.001 inch
Reading of Linear Scale = Pitch of Linear scale x Number of divisions on Linear Scale just before the
                                             zero of Vernier Scale
                                          = 0.025 inch x 45 = 1.125 inch
Reading of Vernier Scale = Least count of Vernier Scale x Number of divisions of Vernier Scale
                                              aligned with the marking of Linear Scale
                                           = 0.001 inch x 14 = 0.014 inch
Total Reading = Reading of Linear Scale + Reading of Vernier Scale
                         = 1.125 inch + 0.014 inch = 1.139 inch

No comments: